Our Search for ACH: Determining Infiltration with a Blower Door Test

- By Jake VP, Energy Circle Content Writer

 

Whether you’ve followed parts one, two, and three of our ventilation series, or attended our recent webinar where Energy Circle CEO Peter Troast got into the specifics about the ventilation equipment that Kevin Brenner utilizes for his New York-based home performance business, Healthy Home Energy & Consulting, there is a lot of information to absorb. But we still wanted to know more about our workspace as we look toward a new normal, and a future where we can work in our own office again. 

In our three-part series on ventilation, we started on a journey to find our total air changes per hour (ACH), which is an accumulation of our active ventilation + natural + infiltration + filtration. So far, our ventilation stat lines are as follows:

Ventilation: .3 ACH from our mechanical ventilation

Natural: 0 (In our everyday office habits, we keep all windows closed)

Infiltration: ?

Filtration: 1.56 (more on this later)

The only way to find the missing puzzle piece, our infiltration from air leakage, was to schedule a blower door test. We contacted a local, independent energy auditor and rater here in Maine, Bill Winkel, and scheduled a blower door test for our office. 

How Leaky Is Our Office?

We have always known that there were some major leaks throughout our workspace. From the drafts throughout the hallways, to the constant condensation in some of the windows, we were sure we would find some form of leakage to contribute to our total ACH.

The leaky nature of our office was confirmed almost immediately, when Bill informed us that his single-fan Minneapolis Blower Door could not reach 50 pascals when depressurizing our space. The DG-1000 pressure gauge accounted for this, and gave us an estimated total ACH of 4.33 from air leakage at 50 pascals—a projection that Bill anecdotally says is accurate to within 10%.

In order to calculate the approximate ACH at natural pressures, or ACH(nat), we can take that ACH50 4.33 and divide it by 20 (the simple approach according to our friend Allison Bailes at Energy Vanguard):

4.33/20 = .21 ACH(nat)

 

Where We Felt It the Most

While the fan was running, we took a walk with the infrared thermal camera to try and locate areas of egregious leakage. And while this may be the only time I ever take this position, it was unfortunate that it was such a nice day here in Maine! The medium temperatures inside as well as outside meant there was not enough delta-T to notice anything from the infrared images. 

We could, however, walk around to each individual area and feel the drafts. Nearly every room had some form of leakage, but the two areas we noticed it the most were in Peter’s office (with a window on the front facade of the building where there apparently isn’t much integrity between the brick and the framing) and the ventilated elevator shaft.

What We Learned from Our Blower Door Test

Now that we have the official results in, and have combined them with what we learned about our state of the art HRV, we can calculate our estimated combined ACH and ACH(nat): 

Estimated Combined ACH for our 103,416 cubic feet: 0.51 ACH

 

The Next Step--Filtration

The next step in our journey is to account for any of the “bonus” ACH we can claim from our three portable air purifiers. On September 28, we turned on 3 Levoit Core 300 HEPA air purifiers, each with a Clean Air Delivery Rate (CADR) of 135 CFM. This translates into an additional 1.68 ACH: (MATH HERE).   , In the coming weeks, we may also add additional filtration from the infamous “Hobo HEPA” --a MERV 13 furnace filter duck taped to a box fan. (This DIY ventilation device could be straight out of an episode of the Red and Green Show, and has been made popular in homes dealing with excessive wildfire smoke up and down the west coast).

So, accounting for all the types of air exchange, we can now calculate ACH for the office. 

.3 ACH (From the HRV) + .21 ACHnat + 1.68 ACH* (from air purifiers)= 2.19 ACH

*While the Harvard School of Public Health calculator clearly says that filtered air is additive, we recognize that there isn’t full agreement on this within the building science community. It does seem questionable to us that 100% of ACH from filtration and none from any other source is an equivalently healthy environment.

How Much Ventilation Do We Need?

The ongoing theme of this autobiographical series is that even with the best equipment, and elevated leakage numbers, we are still a long ways from the recommended 5 ACH that the Harvard School for Health is currently suggesting for American schools, or 3 ACH that’s been batted around for offices, amidst the Covid-19 pandemic. Based on the expert industry friends we’ve consulted while doing this, we are feeling confident that the air exchange rate in the office is at a level that would mitigate risk should the virus get into our space, particularly in light of most of the Energy Circle team still working from home.

We may not be the medical experts when it comes to keeping the built environment safe, but we are paying close attention to what the medical experts are recommending. In the coming weeks, we will continue monitoring our IAQ devices to track the effectiveness of our collective indoor environment, while also staying abreast of the evolving science around keeping our workplaces, schools, and homes as safe as possible. 

 

Looking for some help marketing your ventilation services? Get in touch with us today. 

E-mail me when people leave their comments –

You need to be a member of Building Performance Community to add comments!

Join Building Performance Community

Don Fugler replied to Tom Phillips's discussion Kitchen Ventilation Resources in Kitchen Ventilation
"Another general resource is the indoor air quality guidelines of Health Canada at: https://www.canada.ca/en/health-canada/services/air-quality/residen...
These are particularly important if you would like to have some basic information on the health…"
yesterday
Don Fugler replied to Don Fugler's discussion Links to resources in Low-cost residential particle monitoring
"Here is a link to the Health Canada site that references indoor air quality guidelines: https://www.canada.ca/en/health-canada/services/air-quality/residen...
If you want to explore the arcane world of oxides of nitrogen or volatile organic…"
yesterday
Joe Hughes posted a blog post
This week we welcome back one of our favorite medical contributors and epidemiology of infectious disease expert, Dr. Alan P. Zelicoff MD. Dr. Zelicoff has been educating the IAQ Radio+ audience about biological weapons and infectious diseases since…
yesterday
ovacen liked Emily Ambrose's video
yesterday
Emily Ambrose posted a video
Video has long been recognized as a vital communications tool for contractors, particularly around some of the complex topics in building science and renewables. But in 2020, Energy Circle saw breakout performance from video as it turned from just…
Thursday
Emily Ambrose posted a blog post
 - By Jake VP, Content Writer Even after all of our meetings here at Energy Circle had gone virtual, one part of our everyday office conversations remained: We loved to talk about the latest streaming series and movies we’ve all been watching at…
Thursday
Horace Douglas Hunt, Jr. replied to Diane Chojnowski's discussion States & Cities Are Driving Climate & Clean Energy Progress
"Good article. Maybe one day soon Clean Air wont be thought of as "Unachieable". "
Thursday
Mark Fetsko @ULTRA*GLAZE, LLC liked Mark Fetsko @ULTRA*GLAZE, LLC's blog post Winter Window Inserts
Thursday
Emily Ambrose’s video was featured
The federal solar tax credit (ITC), has long reigned as one of solar energy’s most important demand drivers. But the turmoil in Washington and the step downs in the credit have created some market uncertainty and confusion in the minds of solar…
Thursday
Building Performance Association’s blog post was featured
Last week, the Building Performance Association submitted comments on the Pennsylvania Environmental Quality Board’s (EQB) proposed amendment to Chapter 145 to establish a trading program for carbon dioxide emissions and join the Regional Greenhouse…
Thursday
Building Performance Association posted a blog post
Last week, the Building Performance Association submitted comments on the Pennsylvania Environmental Quality Board’s (EQB) proposed amendment to Chapter 145 to establish a trading program for carbon dioxide emissions and join the Regional Greenhouse…
Thursday
Building Performance Association’s blog post was featured
Late last year, on December 27, 2020, Congress passed and the President signed a massive end-of-year package that included FY2021 government funding, a small-scale energy bill, a tax extension, and COVID relief provisions.
Following is a brief…
Thursday
More…